0.25m3/sec December to March, 0.5m3/sec April, May, October and November, 2m3/sec June to September
Capacity Factor
48%
Average Annual Energy
105GWh
Intakes
Existing intakes in Aberfeldie Dam, one originally in service, one blanked off, modified to produce two identical intakes of 19.25m3/sec capacity.
Waterway
Low Pressure Conduit (LPC) ~850 m buried 3.35m (132”) dia. Weholite HDPE plus ~150m surface-mounted 2.9m (114”) dia. steel pipes; Steel surge tank 15m high 13m dia. at junction of the LPC and HPP; 150m long 2.74m (108”) dia. steel High Pressure Penstock (HPP) down cliff face immediately behind powerhouse.
Turbines
3 x 8.33MW horizontal axis Francis
Generators
13.8kV direct-coupled synchronous
Powerhouse
Concrete substructure, steel superstructure
Switchyard
At powerhouse, step-up 13.8 to 69kV
Transmission Line:
None – direct connection to grid at switchyard
Design Earthquake:
BC Building Code – 1:2,500 event