Table 4: Validation of the proposed predictor for Sc for bell mouth vertical intakes

S.No dmm Vm/s Sc mm gm2/sec F R Sc Calculated % error
1 29.40 0.60 14 0.00 1.12 17640 13.52 3.41
2 20.75 1.20 16 0.00 2.66 24900 15.04 6.03
3 20.75 4.05 30 0.00 8.98 84038 28.44 5.20
4 11.50 5.80 20 0.00 17.27 66700 22.21 -11.04
5 11.50 6.76 110 0.00 20.13 77740 98.52 10.64
6 50.00 9.00 90 0.00 12.85 450000 82.71 8.10
7 27.00 4.35 40 0.00 8.45 117450 35.86 10.35
8 27.00 9.50 55 0.00 18.46 256500 53.99 1.83
9 74.60 1.06 235 0.00 1.24 79076 188.39 19.84
10 74.60 3.65 432 0.01 4.27 272290 463.88 -7.38
11 74.60 4.25 460 0.01 4.97 317050 523.56 -13.82
12 74.60 1.06 330 0.01 1.24 79076 250.94 23.96
13 74.60 4.25 626 0.01 4.97 317050 725.88 -15.96
14 50.00 2.35 340 0.01 3.36 117500 257.90 24.15
15 27.00 4.35 375 0.01 8.45 117450 286.04 23.72
16 27.00 6.20 432 0.01 12.05 167400 381.73 11.64
17 27.00 8.00 500 0.01 15.54 216000 453.88 9.22
18 50.00 6.75 380 0.02 9.64 51136 363.27 4.40
19 50.00 7.50 395 0.02 10.71 56818 395.76 -0.19
20 74.60 3.68 415 0.04 4.30 26146 460.96 -11.07
21 74.60 4.28 438 0.04 5.00 30408 523.53 -19.67
22 50.00 7.50 470 0.03 10.71 49342 485.00 -3.19
23 74.60 1.05 265 0.003 1.23 6528 230.19 13.13
24 74.60 4.28 538 0.06 5.00 26607 640.97 -19.25
25 50.00 2.35 330 0.03 3.36 15064 266.12 19.36
26 50.00 7.50 540 0.05 10.71 48077 666.12 -23.36