Table 3: Validation of the proposed predictor for Sc for flat vertical intakes

S.No dmm Qm3/sec Vm/sec Sc (obs) mm gm2/sec F g/Vd R Sc (cal) mm % error
1 101.6 0.001908 0.235 172 0.0298 0.236 1.246 23914 183 -6.4
2 101.6 0.001614 0.199 165 0.0285 0.199 1.410 20231 155 5.9
3 82.0 0.001429 0.271 159 0.0247 0.302 1.112 22197 176 -10.5
4 82.0 0.001055 0.200 119 0.0226 0.223 1.377 16381 130 -9.5
5 50.8 0.000964 0.476 198 0.0128 0.674 0.53 24157 201 -2.4
6 50.8 0.000936 0.462 179 0.0151 0.654 0.64 23450 198 -10.8